ABB B&R Automation Runtime
p a href= https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-141-04.json strong View CSAF /strong /a /p h2 Summary /h2 p strong An update is available that resolves a vulnerability identified by B amp;Rs internal security analysis in the product versions listed as affected in this advisory. An attacker who successfully exploited these vulnerabilities could take over a remote session or execute code in the context of the user’s browser session. /strong /p p The following versions of ABB B amp;R Automation Runtime are affected: /p ul li Automation Runtime lt;6.4, 6.4 (CVE-2025-3449, CVE-2025-3448, CVE-2025-11498) /li /ul div class= csaf-table table class= tablesaw tablesaw-stack data-tablesaw-mode= stack data-tablesaw-minimap thead tr th role= columnheader data-tablesaw-priority= persist CVSS /th th role= columnheader Vendor /th th role= columnheader Equipment /th th role= columnheader Vulnerabilities /th /tr /thead tbody tr td v3 6.1 /td td B amp;R /td td ABB B amp;R Automation Runtime /td td Generation of Predictable Numbers or Identifiers, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting'), Improper Neutralization of Formula Elements in a CSV File /td /tr /tbody /table /div h3 Background /h3 ul li strong Critical Infrastructure Sectors: /strong Energy /li li strong Countries/Areas Deployed: /strong Worldwide /li li strong Company Headquarters Location: /strong Switzerland /li /ul hr h2 Vulnerabilities /h2 div class= csaf-accordion p a class= csaf-accordion-toggle-all href= # Expand All + /a /p div class= csaf-accordion-item h3 a class= csaf-accordion-toggle href= # CVE-2025-3449 /a /h3 div class= csaf-accordion-content p A Generation of Predictable Numbers or Identifiers vulnerability in the SDM component of B amp;R Automation Runtime versions before 6.4 may allow an unauthenticated network-based attacker to take over already established sessions. /p p a href= https://www.cve.org/CVERecord?id=CVE-2025-3449 View CVE Details /a /p hr h4 Affected Products /h4 h5 ABB B amp;R Automation Runtime /h5 div class= ics-vendor-version-status div class= ics-vendor strong Vendor: /strong br B amp;R /div div class= ics-version strong Product Version: /strong br Automation Runtime lt;6.4 /div div class= ics-status strong Product Status: /strong br fixed, known_affected /div /div div class= ics-remediations h6 Remediations /h6 p strong Vendor fix /strong br The problem is corrected in Automation Runtime 6.4. The System Diagnostic Manager (SDM) is disabled by default in Automation Runtime 6 and is not intended be enabled on active systems located outside properly secured production networks or in facilities lacking adequate physical and logical access controls to prevent any form of unauthorized interaction. For customers who use SDM on their systems, B amp;R recommends applying the update based on risk assessment at the earliest convenience. The process to install updates is described in the
Sign in to read the full article
Create a free account to access all news, downloads, and community features
Originally published by CISA
Source: https://www.cisa.gov/news-events/ics-advisories/icsa-26-141-04
This article is shared for informational purposes. All rights belong to the original author and publisher. If you are the copyright holder and would like this content removed, please contact us.